SECTION 2 HARDWARE DESCRIPTION
17
in the next frame as the data pulse occurred that triggered the
signal in the preceding frame.
Figure 2-16 8 Inch MFM Operation
All these signals are used by the Phase Comparator which
adjusts VX. The comparator provides Pump Up and Pump Down
signals, where the period of the pump pulse is the same as the
deviation of the incoming data pulse from the window's center.
See Figure 2-15. This figure shows the internal phase signals,
an early and late data pulse, and the corresponding pump pulses.